ACS Logo


Australian Calibrating Services (A'sia) Pty Ltd      Open Day 2008

Australian Calibrating Services - Brisbane Laboratory

NATA Accreditation No: 1239 - Scope Last Changed: 28 May 2007


 

This laboratory complies with the requirements of ISO/IEC 17025 (2005)
Their least uncertainties of measurement are expressed as expanded uncertainties (±)

1.03 Engineering metrology equipment
.25 Electronic indicators, dial gauges and test indicators
Up to 100 mm for compliance with AS 2103
with least uncertainties of measurement of -
(1 + 0.025L) μm for indication errors where L is the scale value in mm
 
.27 Electronic and vernier callipers
Up to 500 mm for compliance with AS 1984
with least uncertainties of measurement of -
(10 + 0.025L) μm for indication errors where L is the scale value in mm
 
.31 Steel rules and measuring tapes
Retractable steel pocket rules
with least uncertainties of measurement of -
(0.15 + 0.13L) mm where L is the scale value in m
Steel rules up to 1 m
with least uncertainties of measurement of -
25 μm
 
1.11 Masses
.02 Industrial mass standards
with least uncertainties of measurement of -
0.4 mg up to 100 g;
20 mg from 100 g to 2 kg;
130 mg from 2 to 20 kg
 
1.12 Weighing devices
 
.01 Precision laboratory balances
with least uncertainties of measurement of -
2 in 10 or 20 μg (whichever is greater) up to 200 g
 
.02 Industrial balances
with least uncertainties of measurement of -
1 in 10 or 1 mg (whichever is greater) up to 30 kg
 
.03 Industrial weighing appliances
5 in 10 or 100 mg (whichever is greater) up to 400 kg

 
1.20 Pressure and vacuum measuring devices Calibration in the range -100 kPa to 70 MPa
with least uncertainties of measurement of -
0.05% or 0.05 kPa (whichever is greater)
On-site calibration of industrial gauges and industrial pressure transducers
with least uncertainties of measurement of -
0.46% from -10 to -20 kPa and 10 to 20 kPa;
0.23% from -100 to -20 kPa and 20 kPa to 70 MPa
 
.01 Pressure gauges
Including test gauges as defined in AS 1349
 
.02 Vacuum gauges (bourdon tube)
Including test gauges as defined in AS 1349
 
.11 Pressure transducers
Self-indicating types and types with voltage, current, resistance and frequency outputs
 
.13 Pressure recorders
1.23 Force measuring devices Calibration at forces up to 10 MN in compression and 3.3 MN in tension
to Grade A requirements of AS 2193
 
.02 Elastic force measuring devices
Devices such as force measuring rings for soils testing machines, hydrostatic weighing
units including those in batching plants
 
.04 Load cells
Including devices used in pre and post-stressing jacks and jacking systems used for
stressing tendons in concrete
 
1.25 Torque measuring devices
.01 Torque wrenches
Up to 1400 N.m
Including on-site calibration
with least uncertainties of measurement of -
0.25% up to and including 3.5 N.m;
0.15% above 3.5 N.m
 
1.26 Testing machines
.01 Tension and universal machines in tension
Calibration at forces up to 3 MN to Grade A requirements of AS 2193 and similar specifications
 
.02 Compression and universal machines in compression
Calibration at forces up to 10 MN to Grade A requirements of AS 2193 and similar specifications
Verification of compression testing machines for concrete including
self-alignment and restraint on tilt tests for compliance with BS 1881 Part 115
 
.11 Vickers hardness machines
Partial and complete calibration except indenter dimensions (clause 2.4.2.2)
from 9.8 to 1176 N to AS 1817 (Sections 3 & 4) and similar specifications
 
.12 Rockwell hardness machines
Partial and complete calibration except indenter dimensions (clause 2.4.1.2b)
to AS 1815 (Sections 3 & 4) and similar specifications

 
.13 Brinell hardness machines
Partial and complete calibration to AS 1816 (Sections 3 & 4)
and similar specifications
 
.14 Rockwell superficial hardness machines
Partial and complete calibration to AS 2025
 
.15 Vickers low-load hardness machines (HV 0.2 to HV 5)
Direct verification and indirect verification except indenter dimensions
from 9.8 to 49 N to ISO 146
 
.16 Vickers micro-hardness machines (less than HV 0.2)
Direct verification except indenter dimensions to ISO 146-2
 
1.27 Ancillary mechanical testing equipment
.01 Portable Brinell measuring microscopes

.02 Indenters for hardness machines

Visual examination
 

Accreditation No: 1239
(Scope Last Changed 28-MAY-07 )

Page last updated: Friday 15 June 2007